Acid Rinse
- Make solution of 1 oz. per 10 gallons of water.
- Circulate the solution for 15-20 minutes at a temperature of 50°-140°F
- Drain, rinse, and sanitize before use.
Acid Wash
- Make solution of 1 oz. per 1 gallon of water.
- Circulate the solution for 15-20 minutes at a temperature of 50°-140°F
- Drain, rinse, and sanitize before use.
Initial Acid Passivation
- After cleaning vessel, make a solution of 5 oz. of Acid #5 to 1 gallon of water.
- Circulate for 15-20 minutes at a temperature of 120°F.
- Drain vessel and ALLOW TO AIR DRY.
- Vessel must air dry in order to achieve successful passivation.
- After letting equipment air dry, rinse before sanitizing.
- Sanitize before use.
Repassivation
- After cleaning vessel, make a solution of 1 oz. of Acid #5 to 1 gallon of water.
- Circulate for 30 minutes at a temperature of 120°F.
- Drain vessel and ALLOW TO AIR DRY.
- Vessel must air dry in order to achieve successful passivation.
- After letting equipment air dry, rinse before sanitizing.
- Sanitize before use.
Reviews